The potential of the hydrocarbon breath test as a measure of lipid peroxidation

来自 Elsevier

阅读量:

43

摘要:

The straight chain aliphatic hydrocarbons ethane and pentane have been advocated as noninvasive markers of free-radical induced lipid peroxidation in humans. In in vitro studies, the evolution of ethane and pentane as end products of n-3 and n-6 polyunsaturated fatty acids, respectively, correlates very well with other markers of lipid peroxidation and even seems to be the most sensitive test available. In laboratory animals the use of both hydrocarbons as in vivo markers of lipid peroxidation has been validated extensively. Although there are other possible sources of hydrocarbons in the body, such as protein oxidation and colonic bacterial metabolism, these apparently are of limited importance and do not interfere with the interpretation of the hydrocarbon breath test. The production of hydrocarbons relative to that of other end products of lipid peroxidation depends on variables that are difficult to control, such as the local availability of iron(II) ions and dioxygen. In addition, hydrocarbons are metabolized in the body, which especially influences the excretion of pentane. Because of the extremely low concentrations of ethane and pentane in human breath, which often are not significantly higher than those in ambient air, the hydrocarbon breath test requires a flawless technique regarding such factors as: (1) the preparation of the subject with hydrocarbon-free air to wash out ambient air hydrocarbons from the lungs, (2) the avoidance of ambient air contamination of the breath sample by using appropriate materials for sampling and storing, and (3) the procedures used to concentrate and filter the samples prior to gas chromatographi determination. For the gas chromatographic separation of hydrocarbons, open tubular capillary columns are preferred because of their high resolution capacity. Only in those settings where expired hydrocarbon levels are substantially higher than ambient air levels might washout prove to be unnecessary, at least in adults. Although many investigators have concentrated on one marker, it seems preferable to measure both ethane and pentane concurrently. The results of the hydrocarbon breath test are not influenced by prior food consumption, but both vitamin E and β-carotene supplementation decrease hydrocarbon excretion. Nevertheless, the long-term use of a diet high in polyunsaturated fatty acids, such as in parenteral nutrition regimens, may results in increased hydrocarbon exhalation. Hydrocarbon excretion slightly increases with increasing age. Short-term increases follow physical and intellectual stress and exposure to hyperbaric dioxygen. Several other factors require further evaluation, including normal ranges in infants and children and the effects on the test of altered diffusion and local lipid peroxidation as a consequence of lung disease. The test seems to be unreliable in smokers, because smoking cigarettes results in impressive increase in ethane and penthane exhalation. Hydrocarbon excretion is increased in a great variety of conditions in which lipid peroxidation was thought to be involved, which confirms both the reliability and the nonspecific nature of the test. Abnormal excretion has been documented in alcoholic and cholestatic liver disease, vitamin E deficiency, pulmonary disease, autoimmune disease, inflammatory bowel disease, ischemia-reperfusion injury, and neurologic disease. In many, if not most, conditions, increased lipid peroxidation is an epiphenomenon instead of playing a pathogenetic role. Therefore, the results of the hydrocarbon breath test should not be regarded in isolation but in the light of clinical and laboratory parameters, including other markers of lipid peroxidation. In conclusion, the hydrocarbon breath test, being noninvasive, has great potential for the assessment of the role of lipid peroxidation in clinical conditions, as well as for the detection and follow-up of lipid peroxidation-induced disease in clinical practice. Because the test is time-consuming and requires a flawless technique, it is yet unclear whether the test will ever proceed to

展开

DOI:

10.1016/0891-5849(94)90110-4

年份:

1994

通过文献互助平台发起求助,成功后即可免费获取论文全文。

相似文献

参考文献

引证文献

辅助模式

0

引用

文献可以批量引用啦~
欢迎点我试用!

关于我们

百度学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们保持学习的态度,不忘初心,砥砺前行。
了解更多>>

友情链接

百度云百度翻译

联系我们

合作与服务

期刊合作 图书馆合作 下载产品手册

©2025 Baidu 百度学术声明 使用百度前必读

引用