摘要:

Advances in FTIR photoacoustic (PA) spectroscopy have significantly extended the scope and utility of the PA technique in the areas of: microparticle spectroscopy, compositional determinations via factor analysis, coal surface oxidation measurements, spectroscopy of highly opaque samples, and PA detector technology. A method is reported for measuring FTIR spectra of single particles in the tens of Am size range which uses a tungsten needle to pick up particles and hold them in the sample chamber of the PA detector. The tungsten needle is initially mounted on a micromanipulator and particle pick-up is performed under a microscope. The needle and sample are then transferred directly to the PA detector sample holder which positions the particle in the IR beam. No sample alignment or thinning are necessary. Compositional determinations of kaolinite and quartz in coal have been performed using the Perkin-Elmer CIRCOM factor analysis program. The IR spectra were collected by DRIFTS and PA methods using synthesized samples of known compositions for the learning set and unknown test samples. The PA spectra yielded slightly better correlations. Coal surface oxidation was studied using a calibrated UV irradiation of coal to generate carbonyl species, thereby gauging the freshness of coal surfaces by how much carbonyl is formed by the UV exposure. FT-IR-PA difference spectra are used to measure the increase in carbonyl. UV generated carbonyl is found to increase with surface freshness. This method avoids the need of a "fresh coal standard" which is difficult to reproduce. The method's probe depth is based on the decay length of UV rather than IR photons in coal resulting in an increase in surface specificity. The linearity of FT-IR-PA spectra as a function of absorbance has traditionally not been maintained at the peaks of strong bands in opaque samples. This leads to peak truncation and reduced spectral contrast. A method to extend linearity using the magnitude and phase information of the PA signal is reported based on the Rosencwaig-Gersho Theory of PA signal generations. Spectra of polymer slabs demonstrate the utility of this approach for enhancing spectral contrast. Developments are reported in PA detector technology which increase the scope of applications that commercial PA detectors can be used for. The new MTEC Photoacoustics Model 200 PA detector operates in diffuse reflectance, photoacoustic, and transmission measuring modes and handles both macro- and microsamples. The Model 200 has a simplified purging system and electronics designed for both fast scan and step scan FT-IR instruments. Spectra from a variety of applications are presented to demonstrate the Model 200 performance.

展开

DOI:

10.1117/12.969512

年份:

1989

通过文献互助平台发起求助,成功后即可免费获取论文全文。

相似文献

参考文献

引证文献

辅助模式

0

引用

文献可以批量引用啦~
欢迎点我试用!

关于我们

百度学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们保持学习的态度,不忘初心,砥砺前行。
了解更多>>

友情链接

百度云百度翻译

联系我们

合作与服务

期刊合作 图书馆合作 下载产品手册

©2025 Baidu 百度学术声明 使用百度前必读

引用