对比剂分次团注联合能量成像获得CTU和 CTA 联合成像的应用研究

来自 EBSCO

阅读量:

2

摘要:

Objective: This study aimed to investigate the application value of fractional bolus injection of a contrast agent combined with double-layer detector spectral CT 50 keV virtual monoenergetic imaging (VMI) in combined imaging of computed tomography urography (CTU) and aortic CT angiography (CTA). Methods: The experimental group included 32 patients who underwent spectral CTU with a Philips IQon dual-layer detector at Beijing Tongren Hospital, Capital Medical University, between March and April 2024. Using fractional bolus injection of a contrast agent and bolus tracking technology, the conventional 120 kVp mixed energy image was reconstructed after scanning for group Al; the 50 keV VMI obtained by spectral reconstruction was group A2. The control group included 32 patients who underwent CTU examination between December 2023 and March 2024 using the same equipment, and the contrast agent split bolus and group injection tracking techniques were used. After scanning, the conventional 120 kVp mixed energy image was reconstructed for group B. The objective evaluation included the CT value, contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR) of the abdominal aorta and bilateral renal arteries, which were compared among the three groups. The Kruskal-Wallis and Nemenyi tests were used to compare the average CT values of the initial, middle, and lower parts of the ureter. Wilcoxon test was used to compare the effective radiation dose between the experimental and control groups. Subjective evaluation was performed by two senior radiologists on the three groups of CTU and CTA images using the 4- and 3-point methods, respectively. The consistency of the subjective scores of the two radiologists was analyzed using the Kappa test. Results: Among the objective evaluation indices, there were statistically significant differences among groups A2, A1, and B. There was a significant difference in the SNR of the bilateral renal arteries between groups Al and B. The effective radiation dose of the experimental group was 15.1% lower than that of the control group, which was significantly different. There was no significant difference in the subjective evaluation of the CTA and CTU images among the three groups. The consistency of the CTA and CTU image scoring results between the two physicians was excellent and good, respectively. Conclusion: If CTU examination was performed by fractional injection of a contrast agent, fusion images of the urinary system and aorta were obtained, which not only had a clear anatomical relationship and the same image quality, but also reduced the effective radiation dose. The 50keV virtual monoenergetic image obtained by spectral reconstruction optimizes the image quality of CTU and CTA and has clinical value.

展开

DOI:

10.15953/j.ctta.2024.148

年份:

2024

通过文献互助平台发起求助,成功后即可免费获取论文全文。

相似文献

参考文献

引证文献

来源期刊

站内活动

辅助模式

0

引用

文献可以批量引用啦~
欢迎点我试用!

关于我们

百度学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们保持学习的态度,不忘初心,砥砺前行。
了解更多>>

友情链接

百度云百度翻译

联系我们

合作与服务

期刊合作 图书馆合作 下载产品手册

©2025 Baidu 百度学术声明 使用百度前必读

引用