The role of plate and screw fixation in occipitocervical fusion in rheumatoid arthritis.
摘要:
STUDY DESIGN: In a clinical retrospective study, the results of occipitocervical fusion in patients with rheumatoid arthritis were studied and analyzed. OBJECTIVES: The results of two different operative techniques were compared. The advantages of screw fixation compared with wiring techniques in this population of patients were investigated. SUMMARY OF BACKGROUND DATA: Numerous different implants have been presented in the literature for occipitocervical fusion in patients with rheumatoid arthritis. The use of wires being the standard fixation technique. METHODS: Occipitocervical fusion was performed in patients with rheumatoid arthritis: 26 patients with the wiring technique and 33 patients with a new Y-plate fixation. The results were compared at a follow-up period of 24 months and 50 months, respectively. Clinical and radiologic results were investigated. RESULTS: The atlantodental distance could be significantly better reduced in the group with the Y-plate fixation and the neurologic improvement in the wiring group was 40%, whereas in the Y-plate fixation 86% of neurologic improvement was observed. Pseudarthrosis was seen in 27% of the wiring technique and in 6% in the plate and screw fixation technique. CONCLUSIONS: In occipitocervical fusion for patients with rheumatoid arthritis, the screw and plate fixation technique provides superior results than other techniques using wire fixations.
展开
DOI:
10.1097/00007632-199411001-00009
被引量:
年份:
1994
通过文献互助平台发起求助,成功后即可免费获取论文全文。