Electrochemical removal of Cr(VI) from aqueous media using iron and aluminum as electrode materials: Towards a better understanding of the involved phenomena

阅读量:

90

作者:

G MouedhenM FekiMD Petris-WeryHF Ayedi

展开

摘要:

In the present work, electrocoagulation process with iron and aluminum electrodes was investigated to deepen the understanding of the mechanism of hexavalent chromium (Cr(VI)) removal. Electrocoagulation treatment efficiency was studied with regards to the abatement of Cr(VI) and the resulting species—namely Cr(III), Fe(II) and/or Fe(III). Unlike iron, aluminum electrodes were found to be unsatisfactory for Cr(VI) removal. To elucidate the removal mechanism of hexavalent chromium, different anode/cathode materials and configurations (Fe/Fe, Pt Ti (platinized titanium)/Fe, Al/Al and Pt Ti/Al) were considered. At nearly neutral pH and considering aluminum electrodes, both electrochemical reduction (Cr(VI) to Cr(III)) at the cathode surface and adsorption on Al(OH) 3 floc mechanisms were responsible for Cr(VI) exhaustion. However, the contribution of the two mechanisms to Cr(VI) removal was not discriminated. On the other hand, in the case of iron electrodes, even though electrochemical reduction may contribute to chromium removal, its influence seemed to be minor since the effect was confined to less than 5% of the removal efficiency. Hence, there was essentially one real root for the reduction of Cr(VI) by electrocoagulation with iron electrodes, and it was proven to be the chemical reduction by Fe(II) anodically generated. Moreover, the resulting Cr(III) was quickly removed from solution, via efficient precipitation as Cr(OH) 3 hydroxides. Besides, the electrodissolved iron remained at low level owing to the precipitation of Fe(OH) 2 and/or Fe(OH) 3. Although chemical reduction by Fe(II) predominantly governed the removal of Cr(VI), acidic pH media was found to promote electrochemical reduction of hexavalent chromium at the cathode and accordingly to enhance Cr(VI) removal efficiency. In contrast, a delay of Cr(III) precipitation and a contamination of the electrolyte by electrodissolved iron were observed under acidic conditions. The effect of supporting electrolyte (Na 2SO 4 and NaCl) on chromium removal was also studied. No conspicuous disparity in the treatment efficiency was noted under the electrocoagulation conditions used.

展开

DOI:

10.1016/j.jhazmat.2009.02.117

被引量:

115

年份:

2009

通过文献互助平台发起求助,成功后即可免费获取论文全文。

相似文献

参考文献

引证文献

辅助模式

0

引用

文献可以批量引用啦~
欢迎点我试用!

关于我们

百度学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们保持学习的态度,不忘初心,砥砺前行。
了解更多>>

友情链接

百度云百度翻译

联系我们

合作与服务

期刊合作 图书馆合作 下载产品手册

©2025 Baidu 百度学术声明 使用百度前必读

引用