Development of flow methods for the determination of N-acetyl-L-cysteine in pharmaceutical formulations

阅读量:

32

摘要:

Background: N-acetyl-L-cysteine (NAC) is a synthetic aminothiol antioxidant that has been in clinical use for more than 40 years, primarily as a mucolytic agent and in the management of paracetamol (acetaminophen) poisoning. There is a need for a new, robust, inexpensive, and rapid method of determination of NAC in pharmaceutical formulations, in order to assure proper quality control (QC). Patient safety during therapy, on the other hand, is indirectly linked to proper QC of the medication. Novel flow methods for the determination of NAC, such as the flow-injection method (FIA) or the sequential-injection method (SIA), have been developed and validated. Both methods are kinetic methods, which means that the measurement of the analytical signal is made under dynamic conditions in which the concentrations of reactants and products are changing as a function of time. The proposed flow methods of analysis (FIA and SIA) are interesting alternatives in NAC determinations instead of conventional batch methods and chromatography with different detectors. The advantages afforded by the flow methods of analysis are high sample frequency, low consumption of sample and reagents, low contamination risks, and significant reproducibility that provides high precision and enhanced selectivity as a result of the kinetic nature of the recorded analytical signal. Furthermore, the proposed flow methods of analysis require very limited laboratory bench space and necessary instrumentation. Methods: The proposed methods are based on the reduction of Cu(II)-neocuproine reagent to Cu(I)-neocuproine with the analyte, in a Britton-Robinson buffer solution (pH 3.0). The non-steady-state absorbance of the formed yellow Cu(I)-neocuproine complex is measured at 458 nm. For the flow-injection method the three-line manifold with one reaction coil was used. Optimization of manifold parameters and experimental conditions were carried out by means of univariate method. The sequential-injection manifold consisted of a Cheminert® M50 pump (VICI Valco), a syringe-free stepper motor-driven pump, a 10-port selection valve model (C25-3180D) with a multiposition actuator control module (EMHCA-CE ; VICI Valco). Both flow systems use a spectrophotometric detector. Results: Using a flow-injection method of analysis, a linear calibration curve is established in a concentration range of 6 × 10−7 to 4 × 10−5 mol/l NAC with a detection limit of 9.4  ×  10−8. On the other hand, using the sequential-injection method of analysis, linearity was obtained in the concentration range of 4 × 10−6 to 3 × 10−4 mol/l. The detection limit was found to be 1.2 × 10−6 mol/l. The proposed methods are simple, rapid, sensitive and reproducible (FIA: RSD 0.9 %, n = 100 ; SIA: RSD 1.9 %, n = 100). In addition, the proposed methods are sensitive enough to enable determination of near-nanomole amounts of NAC without expensive instruments with an analytical frequency of 120 / h (FIA) and 60 / h(SIA). Discussion: The proposed methods can be applied for the determination of NAC in pharmaceutical preparations. Therefore, they could be useful for QC of NAC-containing medications, indirectly improving patient safety during therapy (e. g. by reducing the risk of under- or over-dosage).

展开

会议名称:

21st Scientific Symposium of the Austrian Pharmacological Society. Joint Meeting with the British Pharmacological Society and the Pharmacological Societies of Croatia, Serbia and Slovenia Graz, 16 – 18 September 2015 / Thomas Griesbacher

通过文献互助平台发起求助,成功后即可免费获取论文全文。

相似文献

参考文献

引证文献

辅助模式

0

引用

文献可以批量引用啦~
欢迎点我试用!

关于我们

百度学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们保持学习的态度,不忘初心,砥砺前行。
了解更多>>

友情链接

百度云百度翻译

联系我们

合作与服务

期刊合作 图书馆合作 下载产品手册

©2025 Baidu 百度学术声明 使用百度前必读

引用