Posterior occipitocervical reconstruction using cervical pedicle screws and plate-rod systems.

作者:

K AbumiT TakadaY ShonoK KanedaM Fujiya

展开

摘要:

This retrospective study was conducted to analyze the clinical results in 26 patients with lesions at the craniocervical junction that had been treated by occipitocervical reconstruction using pedicle screws in the cervical spine and occipitocervical rod systems. To evaluate the effectiveness of pedicle screw fixation in occipitocervical reconstructive surgery and to introduce surgical techniques. Many methods of occipitocervical reconstruction have been reported, but there have been no reports of occipitocervical reconstruction using pedicle screws and occipitocervical rod systems for reduction and fixation. Twenty-six patients with lesions at the craniocervical junction underwent reconstructive surgery using pedicle screws in the cervical spine and occipitocervical rod systems. The occipitocervical lesions were atlantoaxial subluxation associated with basilar invagination, which was caused by rheumatoid arthritis in 19 patients and other disorders in 7. The lowest cervical vertebra of fusion in 16 patients was C2, and the remaining 10 patients underwent fusion downward from C3 to C7. Flexion deformity of the occipitoatlantoaxial complex was corrected by application of extensional force, and upward migration of the odontoid process was reduced by application of combined force of extension and distraction between the occiput and the cervical pedicle screws. Solid fusion was achieved in all patients except two with metastatic vertebral tumors who did not receive bone graft for fusion. Correction of malalignment at the craniocervical junction was adequate, and postoperative magnetic resonance imaging showed improvement of anterior compression of the medulla oblongata. There were no neurovascular complications of cervical pedicle screws. Occipitocervical reconstruction by the combination of cervical pedicle screws and occipitocervical rod systems provided the high fusion rate and sufficient correction of malalignment in the occipitoatlantoaxial region. Results of this study showed the effectiveness of cervical pedicle screw as a fixation anchor for occipitocervical reconstruction.

展开

DOI:

10.1007/s10164-008-0148-2

被引量:

657

年份:

1999

通过文献互助平台发起求助,成功后即可免费获取论文全文。

相似文献

参考文献

引证文献

辅助模式

0

引用

文献可以批量引用啦~
欢迎点我试用!

关于我们

百度学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们保持学习的态度,不忘初心,砥砺前行。
了解更多>>

友情链接

百度云百度翻译

联系我们

合作与服务

期刊合作 图书馆合作 下载产品手册

©2025 Baidu 百度学术声明 使用百度前必读

引用