A Diagnostic Programme for Quantitative Analysis of Proteinuria

来自 NCBI

阅读量:

40

作者:

W HofmannWG Guder

展开

摘要:

A spectrum of quantitative methods was adapted to the Kone Specific Analyser for the purpose of recognizing, quantifying and differentiating various forms of proteinuria. Total protein, IgG, albumin and alpha 1-microglobulin (measured by turbidimetry), N-acetyl-beta-D-glucosaminidase activity and creatinine (measured photometrically), were measured in undiluted urine; in addition alpha 1-microglobulin was measured in serum. Within and between run precision, accuracy and linearity of the turbidimetric methods were in good agreement with nephelometric procedures. All turbidimetric methods exhibited a correlation coefficient r greater than 0.98 when compared with the radial immunodiffusion procedure as reference method. Total protein measured turbidimetrically with the Kone Specific Analyser was in good agreement with the manual biuret procedure. The low detection limits and linearities allowed quantification of urine analytes from the lower range of normals up to ten times the upper limit of normals. The measured analytes exhibited stability in urine at pH 4-8 over at least seven days at 4-6 degrees C and -20 degrees C. Only IgG showed a significant loss (up to 30 percent), when measured after storage at -20 degrees C. Quantities per mol creatinine showed significantly lower intra-individual and inter-individual variability than quantities per liter. In 31 normal persons, the intraindividual variation was lowest for N-acetyl-beta-D-glucosaminidase activity (13%) and highest for total protein (33%), when measured in the second morning urine on 5 consecutive days. When related to creatinine, results obtained in the second morning urine showed no significant differences from those in 24 h urine, except for alpha 1-microglobulin which gave lower values in 24 h urines. The upper normal limits, calculated as the 95% ranges, were determined from 154 urines of 31 individuals. Nearly all analytes showed an asymmetric distribution. Because of a wide tailing of the upper limit, preliminary upper normal limits were set above this range: (table; see text) Application of the newly adapted programme to unselected urines sent for urine analysis revealed a threefold increase in the proportion of results outside the normal ranges, compared with the routinely used protein test strip procedure. All additional positive urines exhibited either signs of glomerular or tubular proteinuria. Determination of albumin or N-acetyl-beta-D-glucosaminidase excretion was sufficient to detect these additional cases.

展开

DOI:

10.1515/cclm.1989.27.9.589

被引量:

166

年份:

1989

通过文献互助平台发起求助,成功后即可免费获取论文全文。

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献

参考文献

引证文献

辅助模式

0

引用

文献可以批量引用啦~
欢迎点我试用!

关于我们

百度学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们保持学习的态度,不忘初心,砥砺前行。
了解更多>>

友情链接

百度云百度翻译

联系我们

合作与服务

期刊合作 图书馆合作 下载产品手册

©2025 Baidu 百度学术声明 使用百度前必读

引用