In situ remediation of contaminated ground water: The funnel-and-gate system
摘要:
The funnel-and-gate system for in situ treatment of contaminant plumes consists of low hydraulic conductivity cutoff walls with gaps that contain in situ reactors, such as reactive porous media-, that remove contaminants by abiotic or biological processes. Funnel-and-gate systems can be installed at the front of plumes to prevent further plume growth, or immediately downgradient of contaminant source zones to prevent contaminants from moving into plumes. Cutoff walls (the funnel) modify flow patterns so that ground water flows primarily through high conductivity gaps (the gates). This approach is largely passive in that after installation, in situ reactors are intended to function with little or no maintenance for long periods. This approach contrasts with the energy and maintenance-intensive character of pump-and-treat systems. This paper describes the funnel-and-gate concept, and uses two-dimensional computer simulations to illustrate the effects of cutoff wall and gate configuration on capture zone size and shape and on the residence time for reaction of contaminants in gates.
展开