Measured and Simulated Cooling Performance Comparison; Insulated Concrete Form Versus Frame Construction

阅读量:

60

作者:

D ChasarN MoyerA. RuddD ParkerS Chandra

展开

摘要:

Four occupied homes near Dallas, Texas were monitored to compare cooling energy use. Two homes were built with typical wood frame construction, the other two with insulated concrete form (ICF) construction. Remote data loggers collected hourly readings of indoor and outdoor temperature, relative humidity, furnace runtime fraction, total building electrical energy and HVAC energy use. Data was recorded from January through August 2000. Analysis of the measured data shows that insulated concrete form (ICF) construction can reduce seasonal cooling energy use 17 19% over frame construction in two-story homes in the North Texas climate. This result includes adjustments to compensate for differences in miscellaneous energy use, (e.g. lights & appliances), and duct leakage. While each home pair had the same floor plan, elevations and orientation there were some differences that were not accounted for in the measured results. These included occupant impacts, exterior wall color (absorptance) and the absence of an attic radiant barrier in one ICF home. In addition to analyzing the measured data, two sets of DOE2 simulations were performed. An initial comparison of ICF and frame homes modeled in their as-built condition was followed by a comparison of homes modeled with identical features except for wall construction. Both analyses showed a 13% annual cooling energy savings for ICF over frame construction. This result is comparable to a similar simulation study (Gajda 2001) of a two-story home in the Dallas climate, which saved 15% annually on both heating and cooling.

展开

被引量:

9

年份:

2002

通过文献互助平台发起求助,成功后即可免费获取论文全文。

相似文献

参考文献

引证文献

引用走势

2016
被引量:6

辅助模式

0

引用

文献可以批量引用啦~
欢迎点我试用!

引用