Real-Time Measurements of SO <sub/>2</sub> , H <sub/>2</sub> CO, and CH <sub/>4</sub> Emissions from In-Use Curbside Passenger Buses in New York City Using a Chase Vehicle

来自 NCBI

阅读量:

37

摘要:

The Aerodyne Mobile Laboratory "chased" in-use curbside passenger buses operated by various operators in New York City. With the cooperation of New York State's Metropolitan Transit Authority, the relationships between the emissions of the several gas-phase species and particulate loadings were investigated across several bus technologies, bus types, and fuels (diesel, ultralow sulfur diesel, and compressed natural gas, CNG). The CNG buses followed did not employ an oxidation catalyst. The buses characterized were not prescreened in any fashion and were measured while deployed on their normal in-service routes. This paper focuses on the fuel-based mass emissions of SO2, H2CO, and CH4, measured using tunable infrared laser differential absorption spectroscopy. Sulfur dioxide emissions from buses known to be burning ultralow sulfur diesel (<30 ppmm S) were 16 times lower than those from buses burning normal commercial diesel fuel, nominally less than 300 ppmm sulfur. Emissions of formaldehyde and methane from in-use CNG buses were 15 times greater than those from diesel powered buses.

展开

DOI:

10.1021/es0482942

被引量:

68

年份:

2005

通过文献互助平台发起求助,成功后即可免费获取论文全文。

相似文献

参考文献

引证文献

引用走势

2012
被引量:11

辅助模式

0

引用

文献可以批量引用啦~
欢迎点我试用!

引用