A comparison of tracer kinetic models for T1-weighted dynamic contrast-enhanced MRI: Application in carcinoma of the cervix
摘要:
The Tofts tracer kinetic models are often used to analyze dynamic contrast-enhanced MRI data. They are derived from a general two-compartment exchange model (2CXM) but assume negligible plasma mean transit time. The 2CXM estimates tissue plasma perfusion and capillary permeability-surface area; the Tofts models estimate the transfer constant Ktrans, which reflects a combination of these two parameters. The aims of this study were to compare the 2CXM and Tofts models and report microvascular parameters in patients with cervical cancer. Thirty patients were scanned pretreatment using a dynamic contrast-enhanced MRI protocol with a 3 sec temporal resolution and a total scan duration of 4 min. Whole-tumor parameters were estimated with both models. The 2CXM provided superior fits to the data for all patients (all 30 P values trans (mean = 0.35 ± 0.26 min−1</sup
展开
关键词:
dynamic contrast-enhanced magnetic resonance imaging tracer kinetic model cervical cancer perfusion capillary permeability
DOI:
10.1002/mrm.22217
被引量:
年份:
2010