Occipitocervical Revision Surgery Using the Bicortical Screw and Plate System for Failed Craniovertebral Junction Stabilization

阅读量:

58

作者:

Y SunF YangHN MaL GongYL WangJP SongQY HaoMS Tan

展开

摘要:

Background: To evaluate the clinical efficacy and safety of the modified technique utilizing the occipital bicortical screws and plate system in occipitocervical revision surgery. Methods: Between October 2010 and May 2018, 12 consecutive patients were retrospectively evaluated. All patients had posterior occipitocervical resurgery utilizing modified technique of bicortical screws and occipital plate. The measurements of extracranial occiput on midline were conducted on computed tomography (CT) scans. The thickness of the occipital bone at the location of external occipital protuberance and below 15 mm were evaluated, respectively. For the procedure, the trajectory was drilled perpendicular to the external occipital protuberance for the specified depth with a depth-limited drilling, 2 mm away from the internal bone plate, then the trajectory was deepened at intervals of 1 mm each time until reaching the internal bone plate. Meanwhile, a probe was used to explore all the walls of the trajectory. Bicortical screws were inserted to the occipital plate and the depth of penetration was less than 2 mm from the internal bone plate. Clinical efficacy and radiographic evaluation were followed up. Results: The thickest point was the external occipital protuberance, which was 15.49 ± 1.47 mm and decreased gradually on the midline to 13.41 ± 1.60 mm at below 15 mm. Twelve cases (mean age 41.17 years; range, 24–62 years), including five males and seven females, were followed up for 24.08 months (14–32 months). The interval time was 40.42 months (3–156 months) after the initial operation. At the final follow-up, JOA score increased from 8.58 ± 2.53 before surgery to 12.67 ± 1.84 (P < 0.05) and VAS score improved from 6.17 ± 1.21 to 2.08 ± 1.32 (P < 0.05). Besides, clinical symptoms were relieved in all patients after revision surgery. All patients had rigid internal fixations with bone fusion and no major complications occurred. Conclusions: Posterior occipitocervical plate-screw system with bicortical screws had the advantages of safety, simple and promising efficacy without excessive tissue release or intraspinal manipulation, proving that it's valuable as a modified technique for occipitocervical revision surgery.

展开

DOI:

10.1111/os.13086

年份:

2022

通过文献互助平台发起求助,成功后即可免费获取论文全文。

相似文献

参考文献

引证文献

辅助模式

0

引用

文献可以批量引用啦~
欢迎点我试用!

关于我们

百度学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们保持学习的态度,不忘初心,砥砺前行。
了解更多>>

友情链接

百度云百度翻译

联系我们

合作与服务

期刊合作 图书馆合作 下载产品手册

©2025 Baidu 百度学术声明 使用百度前必读

引用